Description
Home Electronic Component Chips Sensor Arduino Module Raspberry Pi DC 12~72V/AC 90-250V 10A MH1210W Temperature Humidity Controller Thermostat Popular Popular Product Introduction AC 90-250V Features: A mini temperature controller. With large and clear LED display for better readability. Wide temperature measuring range. Heating and cooling control. Temperature calibration function. Delay protection function. All parameters can be set to default setting after short circuit. Can be used for domestic freezer, water tanks, refrigerator, industrial chiller, boiler, steamer, industrial equipments and other temperature-controlled systems. Specifications: Working voltage: 90~250V±10% Rated current: 10A Power consumption: ≤3W Measurement range: -50~110 Celsius degree Measurement precision: 0.5 Celsius degree Measurement error: ±0.3 Celsius degree Control precision: 0.1 Celsius degree Working temperature:‐20~70 Celsius degree Temperature sensor: NTC 25 Celsius degree=10K B3435 Item size: 8.5*7.5*3.5cm / 3.4*3*1.4in Item weight: 93g / 3oz Package size: 11*8.5*4.3cm / 4.3*3.4*1.7in Package weight: Approx. 125g / 4.4oz Package Included: 1 * Temperature Controller 1 * Temperature Sensor DC 9-72V Technical Parameters: The working voltage is referenced on the product casing; -40°C ~120°C: Measurement error ± 0. 5 ° C -40°C~120°C: Temperature control accuracy: 1C display accuracy 0. 1°C NTC25°C=10K B3435 ± 1% (1 meter long, regardless of positive or negative) Power supply voltage: DC version is DC12~72V Working environment: Temperature: -20 ° C ~ 70 ° C, humidity: 90% RH no condensation Product size: 75*85*35 (width, depth, height) mm Instructions: Press the S key for 3 seconds to enter the program menu code mode, which displays the code HC. Press the △ or ▽ key to cycle through the HC-CP-LA-PU-CA parameters. To enter a code, press the S key, press the △ or ▽ key to change the desired value and press SET to save and exit. . Control temperature setting: Short press S key (not more than 2 seconds) to display the factory default control temperature. Press △ or ▽ key to change the value well to save automatically. (Press and hold the △ or ▽ key for 2 seconds to quickly adjust the value.) Heating control: When the temperature control method (code HC) is set to H, for example, the set control temperature value is 28 ° C, and the temperature difference is 2 ° C. When the ambient temperature value ≥ the set temperature value (28 °C), the relay opens and closes the output load; when the ambient temperature value ≤ the set temperature value (28 ° C) - the return temperature (2 ° C) and the "delay" is set After the start time, the relay pulls up to start the output load; (if the delay function is not needed, the delay start (code PU) can be set to 0). Cooling mode: When the temperature control method (code HC) is set to C, for example, the set control temperature value is 28 ° C, and the temperature difference is 2 ° C. When the ambient temperature value ≤ set temperature value (28 °C), the relay opens and closes the output load; when the ambient temperature value ≥ set temperature value (28 °C) + hysteresis temperature (2 ° C) and the "delay start" is set After the time, the relay is sucked and the output load is started: (It is recommended that the delay start time is the default time to protect the compressor. If no delay is required, the code (PU) is set to 0) Note: LA minimum lower limit and HA upper limit non-control temperature parameter adjustment, if changed, reduce control temperature range Power button instructions: 1 long press the power button for 5 seconds to shut down, short press the power button to boot 2 In the temperature setting interface and mode setting interface, short press the power button to quickly save the settings and exit the setting interface. Restore the factory default value: After pressing the “▲” button for 5 seconds, all the set parameters of the user will be restored to the factory default values. Parameter lock: Press the ▼ key for 3 seconds to flash “0FF” to indicate that the user has set the parameter to be locked. In this way, the same operation flashes “ON” to indicate that the user has set the parameter lock to be released. (The user can only view and cannot modify after the parameter is locked, but the control degree adjustment is still valid) Fault prompt: When the sensor is short-circuited or when the ambient temperature is detected above the upper temperature limit of 120 degrees, the flashing indicates that the HHH well closes the output load. When the sensor is open or detects that the ambient temperature is below the lower temperature limit of -40 degrees, the LLL is flashed and the output load is turned off. Precautions: In order to prevent high-frequency interference, the sensing time line during installation cannot be bundled with the power supply line and the negative-voltage equipment line, and separate wiring is required. The power supply and the host shall indicate the voltage--cause, the deviation of the rated voltage value is not more than 1% of 0%. The sensor, power line and load output interface are strictly distinguished during installation. The thermostat main unit cannot be installed in places where dripping water, old people, and children are within easy reach. After wiring, check whether the line is correct and then energize, so as to avoid accidentally burning the temperature controller and load equipment. After installation, apply the protective cover to cover. Installation wiring diagram When installing the wiring, please make sure that the working voltage of the load itself and the voltage marked by the thermostat are the same voltage value, otherwise you cannot connect according to this figure. Package Included: 1PCS*Digital MH1210W Temperature Humidity Hygrometer Thermostat Controller 10A Sensor Payment Shipping Refund Payment We accept PayPal only. But we only Accept your Ebay Address ,Please Make sure it's 100% right. Payment must be received in 5 business days of auction closing. Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order. Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched. Shipping We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you contact us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns. Refund All package need to wait 30 days (US only n eed 7-10 days) , Please take care it.Less than 30 days,we can't take a refund . If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it. If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.